Mercury Porosimeter

카탈로그 다운버튼
Features

belpore1.jpg

belpore2.jpg

 

 

belpore3.png

 

 

 

The next step in characterization

 

The BELPORE mercury porosimeters precisely and quickly detect all ccessible pores

in the size range from 1 millimeter to 3.6 nanometers with tepwise equilibrium-controlled pressure increase

from a vacuum up to 414 MPa.

 

 

 

 

Accurate determination of the pore size distribution

 

The BELPORE mercury porosimeters from Microtrac MRB reliably and reproducibly masure pore diameters

from 1 millimeter to 3.6 nanometers at 414 mega-Pascals.

 

“Pascal” is not only a pressure unit, but also stands for the equilibrium-controlled and optimized handling

of the pressure build-up through the so-called “Pressurization by Automatic Speedup and Continuous Adjustment

Logic”, or P.A.S.C.A.L. for short.

 

This automatic control is regulated by the real pore system and permits shorter measuring times under guaranteed

equilibrium conditions as well as the detection of all pores within the specification – and this with up to 20,000

measuring points per analysis.

 

Since only three types of dilatometers are sufficient for all measurement tasks and neither gases nor liquid nitrogen

are required, running costs can be kept significantly low.

 

In addition, the BELPORE LP low-pressure porosimeter is easy to use and has an extended measuring range up to

pore sizes of 1 mm. The vertical degassing and filling with mercury on the BELPORE LP allows the degassing

pressure to be adjusted, making it possible to measure moist samples without changing the moisture content of

the material.

In this way, even moist concrete samples and solvent-containing porous green bodies can be measured unaltered.

 

The mercury porosimeters from Microtrac MRB are available for different pore ranges:
*BELPORE LP (1,000 - 3.25 μm)
*BELPORE MP (15 - 0.0065 μm)
*BELPORE HP (15 - 0.0036 μm)

 

belpore4.png

 

 

 Model BELPORE LP
 Function Degassing, Hg filling, low-pressure porosimetry
 Pressure range Vacuum up to 450 KPa
 Resolution 0.001 kPa in measuring range: vacuum to 0.1 kPA
0.01 kPa in measuring range 0.1 - 450 kPA
 Pressure detection accuracy Better than 0.1% F.S.
 Pore size diameter 180 - 3.25 μm (UMP: 1,000 - 3.8 μm)
 Particle size diameter 330 - 15 μm (UMP: 3,000 - 15 μm)
 Max. detectable volume 0.5 cm³ - 2 cm³
 Volume detection accuracy  Better than 1% F.S.
 Max. number of measuring points  10.000 intrusion
 10.000 extrusion
 Weight & dimensions (W x D x H)  55 kg (121 lbs)
 40 x 67 x 80 cm

 

 Model  BELPORE MP
 Function  High-pressure porosimetry
 Pressure range  0.1 - 228 MPa
 Resolution  0.001 MPa in measuring range 0.1 - 100 MPa
 0.01 MPa in measuring range 100 - 228 Mpa
 Pressure detection accuracy  Better than 0.1% F.S.
 Pore size diameter  15 - 0.0065 μm
 Particle size diameter  40 - 0.015 μm
 Max. detectable volume  0.5 cm³ - 2 cm³
 Volume detection accuracy  Better than 1% F.S.
 Max. number of measuring points  10.000 intrusion
 10.000 extrusion
 Weight & dimensions (W x D x H)  68 kg (150 lbs)
 40 x 67 x 80 cm

 

 Model  BELPORE HP
 Function  High-pressure porosimetry
 Pressure range  0.1 - 414 Mpa
 Resolution  0.001 MPa in measuring range 0.1 - 100 MPa
 0.01 MPa in measuring range 100 - 414 Mpa
 Pressure detection accuracy  Better than 0.1% F.S.
 Pore size diameter  15 - 0.0036 μm
 Particle size diameter  40 - 0.01 μm
 Max. detectable volume  0.5 cm³
 Volume detection accuracy  Better than 1% F.S.
 Max. number of measuring points  10.000 intrusion
 10.000 extrusion
 Weight & dimensions (W x D x H)  68 kg (150 lbs)
 40 x 67 x 80 cm

 

 

 