About AirSTAR CPPP Analyzer
Cooling. The ColdBlock integrated cooling unit is friendly to environment, people and maintenance department. With the capacity to cool down to 105ºC, no external chillers are required. ColdBlock is completely liquid-free.
Concept. AirSTAR CPPP is modular: ColdBlock and CPPP Head are modules that can be combined and used independently from one another. Imagine for instance two ColdBlocks and three CPPP Heads, where one Head is always clean and ready for start on either one of the two ColdBlocks.
Innovation. AirSTAR CPPP is full of innovative technology that makes CPPP testing easier, faster, and more reliable. One example is the cable-free design. Users simply take out the CPPP Head from the ColdBlock and put it in the optional Docking station, and vice versa. All without having to (dis) connect any cables or hoses.
Results. AirSTAR CPPP strictly conforms to applicable ASTM, EN, IP and JIS methods, and results are reliable and precise. Results are stored on the iPad and printed on almost any printer. Other options: connect to Windows PC, send to LIMS and/or email results directly from the iPad.
Features
• Create linear and stepped cooling profiles • Simultaneous CP and PP testing possible • Programmable warm-up of cooling bath before and after test • Specify end-test conditions in program • Monitor and record sample cooling rate data • Define “Start at” temperature for each test • Multiple users with variable access rights can be created by the administrator • Connect multiple CPPP Heads to one ColdBlock • Extensive storage capacity for results, programs, settings, user information and more (16Gb iPad) • Connect with PC (Windows operated systems) for exchanging results and settings via FTP • Data handling options such as: send results in XML to LIMS, make and email PDF • Printing options such as: print PDF via AirPrint and Direct Printing on connected Kiosk printer • Extensive options to calibrate bath jacket, PT-100 probe and electronics
Specification
Methods
Cloud point: ASTM D2500, D5771, EN 219, ISO 3015, JIS K2269
Pour Point: ASTM D97, D5853, D6892, EN 15, ISO 3016, JIS K2269m, Chinese GB/T3535
Sample CP & PP detection
High definition camera
Calibration
Extensive calibration routines for sample + bath jacket temperature Temperature probe offset table. Programmable frequency of calibration notifications
Temperature range
+65°C down to -105°C (-175ºF to 95°F)
Lift mechanism
Microprocessor controlled stepper motor
Test Settings
Test can be started at programmable temperatures. Option for customized time and detection intervals.
Cooling profiles
Stepped and linear cooling profiles customizable (from 1 to 60°C/h). Unlimited storage capacity.
Temperature Measurement
°C or °F; PT 100 class A probe, automatic probe ID detection with built-in calibration data storage. Calibration certificate standard supplied.
Voltage 100–240 VAC, 50/60 Hz Power 150 W Dimensions 16cm x 59cm x 49cm (W x D x H) Weight 25 kg
|