MASS SPECTROMETER FOR QUALITATIVE AND QUANTITATIVE GAS ANALYSIS
Mass spectrometry (MS) is an analytical technique for determining the molecular constituents of pure or mixed gases,
vapors, liquids, and even solids. By bombarding the sample with an electron beam, ions are generated and separated
according to their mass-to-charge ratio. The resulting mass spectrum is a plot of intensity as a function of mass-to-charge ratio.
BELMASS II is a quadrupole mass spectrometer (QMS), a unique mass analyzer used in mass spectrometry.
As a quadrupole, it consists of four cylindrical rods arranged parallel to each other. By applying an oscillating electric field to
the rods, the ions are separated based on the stability of their trajectories as a function of their mass-to-charge ratio (m/z).
An electron multiplier detects the deflected ions. BELMASS II can be combined with various instruments.
Especially in combination with a BELCAT II it can provide important information about the species of the desorbed gases
from gas/vapor mixtures and their breakthrough curves.
*Benchtop quadrupole mass spectrometer
*Heated hose enables the analysis of vapors
*Instrument with built-in mass spectrometer and vacuum pump
Combination with BELCAT II catalyst analyzer
The combination of the BELMASS II mass spectrometer with the BELCAT II makes it possible to evaluate the catalytic reaction (TPReaction)
in more detail. BELMASS ll can record the sample temperature and is suitable for thermal analysis.
OVERVIEW
The mass detector is recognised to be the most efficient detector for qualitative analysis. However, it is difficult to obtain
a good quantitative result because it analyzes only a small amount of gas.
By selecting the most suitable materials and components, Microtrac MRB has successfully developed the mass spectrometer
BELMASS II with a high quantitative capacity. Even ammonia gas can be analyzed by using a heated hose and a dry diaphragm pump.
SPECIFICATIONS
Mass range |
1-200 amu |
Detector |
Faraday cup / secondary electron multiplier |
Min. detection limit |
< 1ppm (gas dependent) |
Resolution |
M/∆M≥2M |
Scan speed |
Auto, 0.01, 0.03, 0.1, 0.3, 1, 3, 10 sec / a.m.u |
Sniffer probe |
1/16 inch capillary tube |
Max. temperature of sniffer probe in heater hose |
200°C (SUS), 120°C (PEEK) (Option) |
Sample gas dosing rate |
Approximately 0.6cc/min (at 1atm) |
Sample gas pressure |
Atmospheric pressure (50-150kPa) |
Vent connection |
1/4 inch one-touch connection |
Max. measurement channels |
16 |
Analysis software |
ChemMaster II: Spectrum image display Area calculation Convert to temp. axis Metal dispersion calculation Distribution Fitting |
Other functions |
System check Analog input Conversion of saved data into CSV |
Interface |
RS232C |
Analog signal input |
1 CH (DC0~10 V, mainly used as a temperature input) |
Dimensions (W x H x D) |
280 x 400 x 600 mm |
Weight |
36 kg |
CE certified |
yes |
Recommended Monitor |
Full HD monitors |
|